RightAngle Reference Manual

  • Welcome to RightAngle Control
  • Introduction
    • User Interface
    • Gauging
    • Tools
    • General panels
    • Application notes
      • Selection of Tools
      • Air bending
      • Large Radius Bending
      • Hemming
      • Coining
  • Home
  • Create
    • From Profile
      • Profile Selection
      • Create/Edit a Profile
      • Extrude
    • Fold Flat DXF
      • Main Screen
      • Create
      • Edit
      • Fold
    • Import 3D model
      • Main screen
      • Unfold
      • Do Tooling
    • Direct Programming
      • Main Screen
      • Add/Remove
      • Settings
      • Run
      • Navigate Bend
      • Corrections
      • Jog
      • Table Programming
    • Setting page
    • Create Tool
  • Edit
    • Sequence
    • Back gauges
    • Tooling
    • Simulation
  • Run
    • Main Screen
    • Model Based WF
      • Setup Sheet
      • Run Program
    • Program Based WF
      • Info Screen
      • Run
    • Corrections
    • Edit Cycle
  • Settings
    • Jog Axes
    • Manual Program
    • Tool Inventory
    • Other Settings
  • Feature list
    • Angle Measurement System (Pre-release)
      • IRIS Plus (Pre-release)
  • Tandem Operation
    • Operation
    • Communication Error
  • Impressum
  • FAQs
    • Licensing
Feature list
/
Angle Measurement System (Pre-release)
/
IRIS Plus (Pre-release)

IRIS Plus (Pre-release)

The Lazer Safe® IRIS Plus is a real-time optical angle measurement and correction system integrated into the press brake’s safety photocells. It uses a laser transmitter and a high-speed camera receiver to measure and correct bend angles during the bending process.

Core capabilities

Real-Time Measurement

The camera captures live frames of the bending profile, measuring the angle and calculating spring-back in real time.

Active Angle Correction

The system sends measurement data directly to the CNC controller, enabling instantaneous depth adjustments to match the programmed angle.

Non-Contact Technology

The system uses optical image analysis instead of physical contact with the sheet metal. This prevents surface marks, eliminates collision risks, and does not restrict operator movement.

High Precision

Measures angles with accuracy better than 0.1° (depending on setup), reducing scrapped parts and the need for test bends.

Operational specifications

Specification Details

Die compatibility

V-openings from 8 mm to 35 mm

Material thickness

1 mm to 4 mm

Workspace size

Optimized for small to medium press brakes. Measurement accuracy may decrease on parts longer than approximately 2.5 m due to light refraction.

Enable IRIS Plus in RightAngle

  1. Navigate to Settings → Other Settings → Machine Settings and set the user level to Service.

  2. In General Parameters, click the Machine tab.

  3. In the Machine section, set the Angle Measurement System type to IRIS Plus.

Enable AMS in RA

Configure IRIS Plus parameters

When IRIS Plus is enabled, two configuration areas become available:

  • AMS tab — Located in Machine Settings → General Parameters.

  • Angle Measurement defaults — Located in Machine Settings → Defaults.

General parameters

Open the AMS tab in General Parameters to view or edit the following settings:

Parameter Range Description

Angle Difference for SB Measure

1° - 30° (default: 10°)

The offset added to the target angle to calculate the initial spring-back measurement angle.

Reduce Pump Speed in Decompression

0 - 1500 RPM

Reduces pump speed during decompression when AMS is active. Applies only when the pressure valve is configured as a servo motor.

Reduce Decompression Gain Factor

1 - 100%

Reduces the gains used during decompression.

Angle Stability Delay Time

0 - 10000 ms

Delay before capturing a stable angle reading from the sensor.

SpringBack Check Delay Time

0 - 10000 ms

Delay before checking the angle change during spring-back measurement.

IRIS Plus communication settings

Configure the following network settings to establish communication with the IRIS Plus sensor:

RA communication settings for IRIS Plus

Interface - Use Ethernet CAT6 straight cable for all the interfaces and define the IP address such that they are all in the same network.

Parameter Default value Description

IP Address

192.168.100.110

Network address of the IRIS Plus device.

TCP Port Number

2345

Used for reference and calibration processes. TCP is not used for real-time streaming because it requires acknowledgment for each transmission.

UDP Port Number

2346

Used for real-time angle data streaming. On the IRIS Plus web page, set the Network Protocol Configuration to Generic Real Time (UDP) and the Real-Time Angle Measurement Type to Angle Result Type 3.

The available angle result types are:

  • Angle Result Type 1 — Basic output: expected angle, measured angle, warp, quality indicator, and tolerance flags.

  • Angle Result Type 2 — Includes measured values with tolerance acceptance status.

  • Angle Result Type 3 — Detailed measurements, quality indicators, and machine data for in-depth analysis. (Recommended)

IRIS Plus sensor

Tolerance settings

Navigate to Default Settings → Bend Program → Angle measure to configure angle tolerances:

Parameter Range Description

Warning tolerance

0.1° - 2° (default: ±0.5°)

If the measured angle deviates from the target by more than this value, a warning is displayed.

Error tolerance

0.1° - 5° (default: ±1°)

If the measured angle deviates from the target by more than this value, an error is displayed.

Both tolerances can also be adjusted for a specific bend in the Corrections → Angle Measurement tab.

Default mode for programs

On the same page, the AMS setting controls how Default mode for 3D program are assigned to bends in 2D and 3D programs:

Mode Description

None

All bends are set to "None" with no reference. Assign Identify or Learned mode to each bend manually.

Auto

AMS modes and references are assigned automatically for all bends.

When set to Auto, some bends may still display as "None". Verify and adjust modes as needed.

Calibration

Calibration ensures accurate angle measurement. Perform calibration when the IRIS Plus sensor is selected.

Reference image

A reference image captures the exact position of the punch tool tip. It is recommended to capture a new reference image at least once a week.

IRIS Plus reference images

Calibration procedure

  1. Run a program and navigate to the setup sheet. The Calibrate button is available for IRIS Plus AMS.

    Setup sheet with Calibrate button
    Setup sheet overview
  2. On the IRIS AMS calibration page, click Tool Align. The AMS captures a reference image and displays a confirmation message.

    IRIS AMS calibration - Tool Align
    IRIS AMS calibration - Capture reference image
    IRIS AMS calibration - Reference image captured confirmation
  3. Mount the suggested calibration tool on the machine and click Done. The calibration page displays three options: Left, Middle, and Right.

    Mount calibration tool
  4. Select the side where the calibration tool is placed and click Calibrate. Repeat for all three sides.

  5. The calibrated values (Acute, Main, and Obtuse) are updated on the page.

    Calibration values for Left Middle and Right
  6. After completing all three sides, click Done.

The calibration tool type depends on the punch shape:

  • Triple-angle side — Use with Straight or Pointed punches.

Triple-angle calibration tool

① Pointed punch

  • Double-angle side — Use with Gooseneck punches.

Double-angle calibration tool

② Gooseneck punch

AMS modes

AMS operates in three modes:

None

AMS is inactive. No angle measurement or correction is performed.

AMS mode selection page

Identify

In Identify mode, AMS measures the spring-back and calculates corrections automatically:

  1. AMS bends to the initial angle (target angle + SB measure angle).

  2. During decompression, it calculates the spring-back and determines the correction.

  3. It applies the correction to achieve the target angle.

  4. The correction values are stored for use by subsequent bends in Learned mode.

Bending sequence: Fast Closing → Slow Closing → SpringBack Measure → Decompression → Pressing → Decompression → Opening

Before BDC settings

AMS mode selection page with Before BDC settings
Before BDC settings
Setting (Range: 1 to 2) Description

Before BDC = 1

AMS bends to the initial angle (Target angle + SB measure angle), then decompresses to calculate spring-back and corrections. On the next pressing, AMS moves to the LDP point targeting: Target angle - SpringBack value.

  • If the target angle is not reached at the LDP point, corrections are applied at the same point.

  • Once the target angle is achieved, the RAM decompresses and AMS recalculates spring-back.

Bending sequence: Fast Closing → Slow Closing → SpringBack Measure → Decompression → Depends on "After BDC" setting

Before BDC = 2

AMS bends to the initial angle (Target angle + SB measure angle), then decompresses to calculate spring-back and corrections. On the next pressing, AMS reaches the target angle, stops, and decompresses to recalculate spring-back. For subsequent pressings, AMS moves to the LDP point targeting: Target angle - recalculated SpringBack value.

  • If the target angle is not reached at the LDP point, corrections are applied at the same point.

  • Once the target angle is achieved, the RAM returns to decompression.

Bending sequence: Fast Closing → Slow Closing → SpringBack Measure → Decompression → SpringBack Measure 2 → Decompression → Depends on "After BDC" setting

After BDC settings

After BDC settings
Setting (Range: 0 to 1) Description

After BDC = 0

AMS measures the final angle after decompression, then proceeds to the opening state. No corrections are applied.
Sequence: Pressing → Decompression → Opening

After BDC = 1

AMS measures the final angle after decompression. If corrections are still required, AMS re-presses to the same LDP point.
Sequence: Pressing → Decompression → Pressing → Decompression → Opening

Learned

AMS mode selection page with After BDC settings

In Learned mode, AMS uses the correction values obtained from a previous Identify bend as a reference:

After BDC settings
Setting (Range: 0 to 1) Description

After BDC = 0

Correction values from the Identify bend are applied. AMS measures the final angle after decompression, then proceeds to the opening state.
Sequence: Fast Closing → Slow Closing → Pressing → Decompression → Opening

After BDC = 1

Correction values from the Identify bend are applied. AMS measures the final angle after decompression. If corrections are still required, AMS re-presses to the same LDP point. This compensates for differences in sheet thickness.
Sequence: Fast Closing → Slow Closing → Pressing → Decompression → Pressing → Decompression → Opening

Setting the reference bend
Select a bend from which Identify mode corrections were obtained. Only bends with the same target angle should be used as a reference.

Set up AMS for a bending program

The AMS workflow is the same for 2D, 3D, and Direct programs. The following example uses a two-bend Direct program:

  1. Set the AMS mode for both bends.

  2. On the Run page, click Correction → Angle Measurement to open the mode selection page.

  3. Set the first bend to Identify and the second bend to Learned, with the reference set to Bend 1.

    Learned mode with reference bend
    In 2D and 3D programs with Default mode for 3D program set to Auto, modes are assigned automatically.
  4. Start the bending process. After the first bend completes in Identify mode, the angle correction and spring-back values are displayed in the Angle field on the Run page.

    Run page showing angle and spring-back values
  5. The correction values from the first bend are applied to the second bend automatically. The final angle is displayed after the second bend completes.

    Run page showing angle and spring-back values

To view detailed angle measurement data:

  1. Navigate to Settings → Other Settings → Machine Settings → General Parameters → Log → Diagnostics.

  2. Enable Show IO Screen and save.

  3. On the Run page, click Numeric and expand Angle Measurement Data.

Angle measurement data on the Run page

Troubleshooting

The following table lists common AMS error messages and their causes:

Error message Cause and resolution

Machine not referenced

The machine has not been homed. Home the machine before attempting to take a reference.

Failed to capture reference image

A disturbance occurred near the tool during reference capture. Ensure the area around the tool is clear and try again.

Release E-stop, press reset and try again

The Emergency Stop is active. Release the E-stop, press Reset, and retry.

Failed to calibrate, check whether multi-tool is mounted at punch tip

The calibration side selected on the IRIS AMS calibration page does not match the side where the calibration tool is mounted. Select the correct side and retry.

AMS - backgauge retraction required to avoid interruption

The flange height is less than 50 mm and the backgauge is within the IRIS sensor range. Add a backgauge retraction to avoid interfering with the measurement.

AMS not able to measure the angle, so manually measure it

Angle measurement is not possible under the current conditions, but the result is within tolerance. This also appears when bending without a part. Measure the angle manually.

IRIS - Received data not valid, check for any interruption
Interruption error message

An interruption occurred during bending. Check for obstructions or disturbances and retry.

AMS - wrap angle exceeds, check sheet flatness or redo ref & calib
Wrap angle error message

The sheet may have burrs or uneven surfaces preventing accurate measurement. Check sheet flatness, and redo the reference and calibration if needed.

Angle deviation greater than [warning tolerance]

The measured angle deviates from the target by more than the warning tolerance (e.g., ±0.5°). Displayed in dull red. Review the bend and adjust if necessary.

Angle deviation greater than [error tolerance]

The measured angle deviates from the target by more than the error tolerance (e.g., ±0.8°). Displayed in bright red. Stop production and investigate the cause.

Contents

  • Core capabilities
  • Operational specifications
  • Enable IRIS Plus in RightAngle
  • Configure IRIS Plus parameters
  • General parameters
  • IRIS Plus communication settings
  • Tolerance settings
  • Default mode for programs
  • Calibration
  • Reference image
  • Calibration procedure
  • AMS modes
  • None
  • Identify
  • Learned
  • Set up AMS for a bending program
  • Troubleshooting