Others
Tonnage
Default tonnage in jog mode
Range |
0.1 to 12 |
Default |
2 |
Units |
KN |
Access |
Standard |
Function
This parameter is used to set the default tonnage for jog mode.
Max tonnage in jog mode
Range |
0.1 to 25 |
Default |
5 |
Units |
KN |
Access |
Standard |
Function
This parameter is not used for now.
Backgauge
Z axis backgauge speed diff percent
Range |
1 to 100 |
Default |
20 |
Units |
% |
Access |
Administrator |
Function
When moving Z1 and Z2 together, the speed difference in percentage with which one BG should move. If moving left (considering operator is standing in front of the machine), Z2 will move slower than Z1. If moving right, Z1 will move slower than Z2.
Use flange height if possible
Range |
Checked/Unchecked |
Default |
Unchecked |
Units |
NA |
Access |
Additional backgauge finger-mode
Range |
Checked/Unchecked |
Default |
Checked |
Units |
NA |
Access |
Standard |
Function
Additional backgauge finger mode provides extra support points for positioning larger or complex workpieces.
Description
Enhances workpiece stability and accuracy during bending by using multiple backgauge fingers for precise alignment.
Z-axes limited velocity
Range |
1 to 33 |
Default |
33 |
Units |
|
Access |
Standard |
Function
Z-axis limited velocity controls the maximum speed of the backgauge’s movement along the Z-axis to ensure safe and precise positioning
Description
When the manual Z-axis is mounted on the machine, the back gauge operates at a slower speed to ensure precision and prevent potential damage